- Use Literature Library to find a wide selection of publications that support Rockwell Automation, Rockwell Software, and Allen-Bradley products, services, and solutions. Access the latest brochures and case studies. Find technical documentation to use our products effectively. Explore product and service content by industry.
- PowerFlex 70 Adjustable Frequency AC Drives Standard Control Firmware, Revision 2.xxx. Summary of Changes The information below summarizes the changes to this PowerFlex® 70 Adjustable Frequency AC Drives User Manual since the July 2014 release. The following information has been added, removed, or updated. Rockwell Automation.
EtherNet/IP Network Configuration User Manual ENET-UM001 Troubleshoot EtherNet/IP Networks ENET-AT003 EtherNet/IP Design, Commissioning, and Troubleshooting Quick Reference Drawings IASIMP-QR023 Ethernet Design Considerations Reference Manual ENET-RM002 PowerFlex®520-Series Drives PowerFlex 525 Adjustable Frequency AC Drive User Manual 520-UM001. Automation is our foundation. We are dedicated innovators delivering smarter, connected solutions to the world around us. Our future is propelled by our long legacy of creating Allen-Bradley integrated control and information solutions that make you as productive as possible.
Rockwell Automation Publication 520-QS001A-EN-E - March 2014
13
PowerFlex 520-Series Adjustable Frequency AC Drive
PowerFlex 525 Control I/O Wiring Block Diagram
04
05
06
07
01
02
03
08
11
12
13
14
15
16
17
18
19
Digital Common
DigIn TermBlk 05
DigIn TermBlk 06
DigIn TermBlk 07/Pulse
Stop
(1)
DigIn TermBlk 02/
Start/Run FWD
(2)
DigIn TermBlk 03/
Direction/Run REV
DigIn TermBlk 08
R1
R2
S1
S2
S+
Relay 1 N.O.
Relay 1 Common
+24V DC
+10V DC
0-10V (or ±10V) Input
Analog Common
4-20mA Input
Analog Output
Opto Output 1
Opto Output 2
RJ45 Shield
Comm Common
Opto Common
+24V
+10V
Safety 1
Safety 2
Safety +24V
Typical
SNK wiring
Typical
SRC wiring
R1
S1
S2
S+
11
12
13
14
15
16
17
Powerflex 525 Parameters Sheet
18
19
R2
R5
R6
01
02
03
04
05
06
07
08
C1
C2
30V DC
50 mA
Non-inductive
Common
24V
(3)
Pot must be
1...10 k ohm
2 W min.
0-10V
0/4-20 mA
SNK
D
igital In
D
igIn T
ermBlk
07
Se
l
Analog O
u
t
J10
J9
J5
Pulse In
SRC
Digital
Input
0/4-20mA
0-10V
SRC
SNK
R5
R6
Relay 2 Common
Relay 2 N.C.
C1
C2

Safe-Torque-Off
(1)
(2) Two wire control shown. For three wire control use a momentary input
on I/O Terminal 02 to command a start. Use a maintained input
for I/O Terminal 03 to change direction.
(3) Only one analog frequency source may be connected at a time. If more than one reference is connected at the same time, an undetermined frequency reference will result.
IMPORTANT
I/O Terminal 01 is always a stop input. The stopping mode is determined by the drive setting.
The drive is shipped with a jumper installed between I/O Terminals 01 and 11. Remove this jumper when using I/O
Terminal 01 as a stop or enable input.